MODEL PROFILE

Air conditioner / Midea

MAP07S1AWT

Find the official source for this exact appliance model.

Signal or code

Error codes and display signals

The official manual linked for this model documents these messages. Some indicators apply only to variants that display them; each entry is labeled as a code, indicator, or status.

Model and error-code facts may be shown in the language of the original source.

Official PDF manual

Jump to manual pages

Open the official PDF at pages that document signals for this model.

MODEL OVERVIEW

About this model: Midea MAP07S1AWT

Midea MAP07S1AWT 7,100-BTU portable AC: exact manual, four verified electronic faults and P1 drainage.

Use the 7,100-BTU room rating, not its sibling's

MAP07S1AWT is the 7,100-BTU DOE smart portable air conditioner that Midea lists for rooms up to 300 square feet. Its exact specification row has Cool, Dehumidify and Ventilate, but says Heat No. The official owner PDF linked from this product page names both MAP07S1AWT and the 5,000-BTU MAP05S1AWT on the cover. That shared manual is suitable for controls and drainage, yet the room rating must be taken from the 7,100-BTU listing. Both listings happen to give a 50.04-pound weight, so do not infer cooling capacity from cabinet mass. The product is marked no longer available on the manufacturer page, but the manual remains useful for an installed appliance. Read the complete model string on the label before comparing room performance or ordering a replacement part.

Source for this detail · midea.comSource for this detail · midea.com · Source page: 1

Make a 300-square-foot room genuinely coolable

A larger nominal room rating still depends on an unobstructed exhaust. The guide requires a flat surface, grounded power, access to the tray drain, at least twelve inches between the cabinet and nearby wall, and clear space beyond the outlet. Its window slider spans 19.4 to 62.2 inches; assemble the pieces for the actual sash and seal the gap. Do not pull the hose taut or bend it sharply, because heat that cannot leave the room returns to the cooling load. Cool is specified for ambient 60 to 95 degrees Fahrenheit and Dry for 55 to 95. When cooling seems poor, the troubleshooting table asks for a clean filter, closed windows and doors, clear exhaust and reasonable room size. A 300-square-foot area with open passages to a larger space exceeds the stated use case.

Source for this detail · midea.comSource for this detail · midea.com · Source page: 8Source for this detail · midea.com · Source page: 9Source for this detail · midea.com · Source page: 12Source for this detail · midea.com · Source page: 13Source for this detail · midea.com · Source page: 37

Treat water collection as its own operating system

This portable unit moves moisture into a bottom collection tray. When it reaches the limit, the panel shows P1 and the machine beeps eight times. Cooling and drying stop, yet the fan can keep moving air; that combination does not imply a stalled compressor. Roll or carry the appliance carefully to a safe drain, open the bottom plug, empty the tray and refit the plug firmly. Only then restart; if P1 returns after proper draining, seek service. Continuous drainage in Dry mode uses a different rear drain and hose, which must slope freely without kinks. Keep these two openings distinct when explaining a leak. The manual recommends washing the air filter roughly every two weeks and draining the bottom tray before storage. Its twelve-hour Fan drying step helps reduce retained moisture when the unit will be put away.

Source for this detail · midea.com · Source page: 18Source for this detail · midea.com · Source page: 34Source for this detail · midea.com · Source page: 35Source for this detail · midea.com · Source page: 36

Keep the diagnostic list within confirmed model scope

On the rendered display page, EH00 is an EEPROM error, EH60 points to the room-temperature sensor, EH61 to the evaporator sensor, and EH0b to communication with the display panel. The final character of EH0b is a lower-case b. EC52 and EC have an explicit 'on some models' note; the product page and cover do not establish those options for this exact portable unit, so they are excluded here. For an electronic code, Midea tells users to turn off and unplug, then use qualified service if a restart does not clear it. The refrigerant is R32 and the safety pages forbid opening or puncturing the circuit. P1 remains a drainage protection rather than one of those four component faults. Photograph the panel to keep characters and case accurate when contacting support.

Source for this detail · midea.com · Source page: 1Source for this detail · midea.com · Source page: 18Source for this detail · midea.com · Source page: 34Source for this detail · midea.com · Source page: 7

Verify app setup against the physical controls

The 7,100-BTU page advertises SmartHome, an Apple Watch and voice-assistant control, while the manual gives SmartHome and Matter setup routes. Matter asks for 2.4-GHz wireless with IPv6 and phone Bluetooth. On a portable unit, pressing the applicable Swing or Power control for three seconds produces AP during enrollment. AP is neither P1 nor an EH sensor error. The manual warns that its pictures cover family variations: a remote button for a feature absent from the real control panel will have no effect. If only the app is offline, first confirm the unit's own buttons still run Cool and Fan. That isolates a network issue from EH0b, which must actually appear on the appliance display before it is reported as panel communication failure.

Source for this detail · midea.comSource for this detail · midea.com · Source page: 17Source for this detail · midea.com · Source page: 18Source for this detail · midea.com · Source page: 31Source for this detail · midea.com · Source page: 19

Verified model details

This description summarizes the linked source documents; check each cited source for your exact model and region.

Manufacturer source

Open official source

Official source linked

Midea 7,100 BTU DOE Smart Portable Air Conditioner MAP07S1AWT

Open official source

If there is a safety risk, stop using the appliance and follow the manufacturer’s instructions.

← Back to all models