MODEL PROFILE

Refrigerator / Midea

MRB19B7AWW

Find the official source for this exact appliance model.

Signal or code

Error codes and display signals

The official manual linked for this model documents these messages. Some indicators apply only to variants that display them; each entry is labeled as a code, indicator, or status.

Model and error-code facts may be shown in the language of the original source.

Official PDF manual

Jump to manual pages

Open the official PDF at pages that document signals for this model.

MODEL OVERVIEW

About this model: Midea MRB19B7AWW

The white MRB19B7AWW combines a reversible-door bottom-freezer layout with five documented LED fault pairs.

Start with the white model and its layout

MRB19B7AWW is Midea Canada's white, 18.7-cubic-foot bottom-mount refrigerator. Its 29.5-inch width and lower freezer distinguish it from a top-mount cabinet, while the 13.07-cubic-foot fresh section and 5.62-cubic-foot freezer define the storage split. The product highlights a reversible door, automatic defrost, electronic controls, a gallon-size door bin and two humidity-controlled produce drawers. This matters when comparing a kitchen's door swing and when deciding which compartment has actually warmed. The owner PDF names this white model and stainless MRB19B7AST on the same cover; the white product page's own documentation API links that exact PDF. Its drawings may vary by model, so use the full rating label and the installed control panel rather than judging by a picture. Ice-maker ready means an optional unit may be fitted; do not assume one is present.

Source for this detail · midea.comSource for this detail · midea.com · Source page: 1

Learn what a healthy panel normally shows

The six numbered lamps serve both settings and fault reporting. Immediately after connection, the entire display appears for three seconds; the medium default then leaves LED2 and LED5 illuminated. The fresh-food scale uses positions 6, 5 and 4, and the freezer scale positions 3, 2 and 1. A press advances the temperature selection, with the new value taking effect after about 25 seconds. Thus two steady lights after startup can simply show selected temperatures. The manual says fault lamps flash in sequence. Before interpreting a pattern, watch long enough to tell flashing from a fixed setting and photograph all six positions. A three-second control hold also enters standby and stops the compressor; a short press resumes. A quiet white cabinet may be in standby rather than suffering a cooling-system failure.

Source for this detail · midea.com · Source page: 16Source for this detail · midea.com · Source page: 17

Set it upright and preserve airflow

A bottom-freezer cabinet is awkward to carry, but the installation limits still apply: Midea says not to tilt it beyond 45 degrees while moving. If it was horizontal for any length of time, stand it upright for 24 hours before plugging in. For normal upright handling, the preparation page gives approximately two hours. Remove shipping foam between condenser and cabinet and use a grounded three-prong receptacle without an extension. After connection, the guide suggests checking operation at roughly 30 minutes; after a longer disconnection, allow four hours of cooling before adding food. The glass shelves should not be lined with foil or paper, because circulation is needed. Wrapping food and drying containers help limit frost even though this model is advertised as automatic defrost. These basic conditions make later temperature observations more meaningful.

Source for this detail · midea.com · Source page: 9Source for this detail · midea.com · Source page: 14Source for this detail · midea.com · Source page: 15Source for this detail · midea.com · Source page: 20

Record the five pairs without guessing a repair

On rendered PDF page 21, LED1 with LED2 indicates the refrigerator temperature sensor; LED1 with LED5, the freezer temperature sensor; LED1 with LED3, the freezer defrost sensor. LED2 with LED4 is the communication fault. The last row prints the unusual label “LED 1 indicator and LED 4 Ambient,” while its explanation says ambient temperature sensor fault. Report LED1/LED4 and that printed wording rather than silently rewriting it. LED1 alone appears in several rows, so a single lit position is not enough. Moreover, the normal medium setting is LED2 with LED5, different from every listed fault pair, and should be steady rather than flashing. Write down the pair, flashing sequence, compartment temperatures and time seen. The chart identifies the suspected area for qualified service; it supplies no owner procedure to open a sensor or circuit board.

Source for this detail · midea.com · Source page: 21Source for this detail · midea.com · Source page: 19Source for this detail · midea.com · Source page: 16

Check doors and food before calling

If the white refrigerator fails to run at all, the troubleshooting table first checks its plug and household breaker. If the reversible door does not seal, move food packages out of the way, clean its gasket and level the cabinet. Warm room air, repeated opening and a large recent food load can extend compressor cycling, so note those conditions alongside a fault indication. A compartment that was disconnected needs its full cooling time; do not treat a quick touch of a shelf as a precise temperature test. Unplug before cleaning and use a nonflammable mild cleaner around the gasket. The manual tells owners not to repair the appliance themselves. If a pair repeatedly flashes after external checks, protect perishable food and contact a technician with the complete MRB19B7AWW model, panel photo, affected compartment and recent transport history. Keep the refrigerant system closed.

Source for this detail · midea.com · Source page: 20Source for this detail · midea.com · Source page: 19Source for this detail · midea.com · Source page: 21Source for this detail · midea.com · Source page: 15Source for this detail · midea.com · Source page: 18

Verified model details

This description summarizes the linked source documents; check each cited source for your exact model and region.

Manufacturer source

Open official source

Official source linked

18.7 Cu. Ft. 30" Bottom Mount Freezer White | Midea CA

Open official source

If there is a safety risk, stop using the appliance and follow the manufacturer’s instructions.

← Back to all models